Maximum height for the purposes of MUZ-R18.2
Maximum height for the purposes of MUZ-R18.2 The following maximum height limits above ground level must be complied with: Assessment criteria where the standard is infringed: Streetscape and visual amenity effects; Dominance, privacy and shading effects on adjoining sites; and The extent to which taller buildings would contribute to a substantial increase in residential accommodation. Location Limit Height control area 1 Greta Point Miramar: Ropa Lane, Maupuia Road and Tauhinu Road 18 metres Height control area 2 Rongotai South Mixed Use Zone Height Control A, B, C, and D 19 metres Height control area 3 Newtown South Tawa: Tawa Junction Tawa: Tawa Street Tawa: Tawa South Takapu Island 22 metres Height control area 4 Glenside Kaiwharawhara Sar Street Kilbirnie North Miramar: Park Road and Weka Street 22.5 metres Height control area 5 Ngauranga: Malvern 24 metres Height control area 6 Shelly Bay 27 metres Fences and standalone walls must not exceed a maximum height of 1.8 metres (measured above ground level). This standard does not apply to: Accessory buildings; Solar panel and heating components attached to a building provided these do not exceed the height by more than 500mm; Satellite dishes, antennas, aerials, chimneys, flues, architectural or decorative features (e.g. finials, spires) provided that none of these exceed 1m in diameter and do not exceed the height by more than 1m; and Lift overruns provided these do not exceed the height by more than 4m.