Outlook space
Outlook space An outlook space must be provided for each residential unit as specified in this standard; All principal living rooms must have an outlook space of a minimum dimension of 4m in depth and 4m in width as shown in the diagrams below; All habitable rooms must have an outlook space of a minimum dimension of 1m in depth and 1m in width; The width of the outlook space is measured from the centre point of the largest window on the building face to which it applies; Outlook spaces may be over driveways and footpaths within the site or over a public street or other public open space; Outlook spaces may overlap where they are on the same wall plane in the case of a multi-storey building; Outlook spaces may be under or over a balcony; Outlook spaces required from different rooms within the same building may overlap; and Outlook spaces must: be clear and unobstructed by buildings; and not extend over an outlook space or outdoor living space required by another residential unit. Assessment criteria where the standard is infringed: The extent to which: Acceptable levels of natural light are provided to habitable rooms; The design of the proposed unit provides a healthy living environment; and The extent of dominance and privacy related effects on adjoining sites.